Start from the inside to ensure that the hole is centered behind the junction box drilling out through the siding.
Coduit entering building from ground siding.
When it is higher from the ground splashing water onto the wood is minimized.
2 yes the conduit runs underground between the garage and house and it enters the house under the ground line.
Check to see the local code requirements.
The lb fitting has no means for support.
3 besides the access.
Wiring in pvc conduit must have at least 18 inches of cover.
Make sure you have at least 1 inch of conduit exposed between the wall of your structure and the end of the conduit.
In some installations using metal conduit the raceway the conduit boxes and connectors serve as the ground for the circuit.
For under ground conduit coming up in to a panel or building duct seal.
Some codes may require rigid metal conduit where it emerges from the ground or some may allow a heavier wall pvc.
The further the better.
It gets wet it rots and it attracts termites.
For under ground conduit coming up in to a panel or building duct seal.
In this way the metal raceway acts in place of the grounding wire that is found in nm cable this is also the main reason why only metal boxes may be used with metal conduit.
Single gang electrical boxes will work but if you have two or more conduit sections connecting to one box buy double gang.
Whatever size conduit you use don t fill it more than 40 percent with wires.
I am assuming a coupling underground is damaged causing the conduit to fill with water when it rains.
1 the garage conduit is dry and the entrance point where the garage conduit enters the ground is dry.
Six inches would not be too far.
Thread the wire through the conduit then attach the conduit to the back of the.
Wiring buried inside rigid metal rmc or intermediate metal imc conduit must have at least 6 inches of earth cover.
The conduit should be supported and then the fitting will be supported.
The male connectors on the ends of the pvc conduit take up quite a bit of room inside the box leaving little room for devices.
If a pipe is running under ground down hill concrete pull box with drain rock at the bottom of the hill.
You may slow it down from above ground entering by seal offs but thats.
Uf cable can be direct buried without conduit with a minimum of 24 inches of earth cover.
What is on the other side of the wall.
If a pipe is.
Step 3 attach the lb fitting to the pvc conduit using pvc glue.